The life sized mannquin
emulates the positioning of a driver or passenger torso
|

|
 |
| The Kanomax Amenity Manikin System is an
optimal solution for precise interior cabin comfort evaluation. The
system measures parameters, such as air velocity, temperature,
humidity, and radiant heat, which all relate to human comfort levels.
One mannequin may be equipped with more than 120 sensors, providing
sophisticated measurements. |
|
|
|
| Applications |

|
- Thermal comfort performance testing
|
| Industries |
- Automobile,
Train, Airplane
- Building,
Architecture
- HVAC system
|
|
|
| Features |

|
- Air Velocity sensor x 36 channels
- Temperature
sensor x 78 channels
- Humidity sensor x
2 channels
- Radiant Heat
sensor x 12 channels
- Simultaneous
measurements up to 4 manikins
- Windows
XP software
|
|
|
| Benefits |
 |
- Up to four mannequins may be measured
simultaneously, for complete interior cabin simulation
- Wireless connection for easy operation
- Graphical software for both real-time
measurement and data retrieval
|
|
|
| Software |
 |
- Data table & Graphical interface
- High resolution measurement
- Excel compatible data output (.csv)
- Save graphic data for review
|
|
Mannequin Specifications
|
Height
|
approx.
170cm (5' 7")
|
Weight
|
40kg
(90lbs, including data processor)
|
Material
|
Plastic
(FRP)
|
|
|
Sensor Allocations by Part
|
|
Air
Velocity
|
Temperature
|
Relative
Humidity
|
Radiant
Heat
|
Head
|
4
|
12
|
1
|
3
|
Upper
Torso
|
12
|
33
|
0
|
5
|
Lower
Torso
|
20
|
33
|
1
|
4
|
Total
|
36
|
78
|
2
|
12
|
|
Sensors Specifications
|
Air Velocity
|
Range
|
0.1
to 5.0 m/s
|
Accuracy
|
0.1
to 2.0 m/s
|
+/-
0.05 m/s
|
2
to 5 m/s
|
+/-
0.10 m/s
|
Temperature
|
Range
|
-33
to 100 C
|
Accuracy
|
+/-
3 C
|
Humidity
|
Range
|
3
to 95 %RH
|
Accuracy
|
3
to 30 %RH
|
+/-
3 %RH
|
30
to 75 %RH
|
+/-
2 %RH
|
75
to 95 %RH
|
+/-
3%RH
|
Radiant
Heat
|
Wavelength
|
0.3
to 40 um
|
Range
|
0
to 1 kw/m2
|
Accuracy
|
+/-
7 %
|
|
|
|
KANOMAX
USA Copyright © 2011 KANOMAX USA, INC. All Rights Reserved.
|
 |
219 US
Hwy. 206, PO Box 372, Andover, NJ 07821
Tel: (973) 786-6386 / Fax:
(973) 786-7586 / info@kanomax-usa.com
|
|