Handheld IAQ Monitor
Model 2211
|
|
|
|
|
 |

|
| The Kanomax IAQ
Monitor 2211 features quick
start-up and high accuracy in measuring carbon dioxide and carbon
monoxide concentration levels in the environment. Temperature and
humidity are also simultaneously measured in ah handy lightweight
design. |
|
|
Applications
|
- IAQ
Investigation
- Ventilation
Testing
- Thermal
Comfort Control
- Monitoring
Toxic Gas
|
|
|
Features
|
- Simultaneously
measures and data log multiple parameters such as: CO, CO2,
Temperature, Relative Humidity, to monitor indoor air quality
conditions.
- Calculates
Dew Point, Web Bulb Temperature, Absolute Humidity, Humidity Ratio and
% Outside Air.
- Built-in
memory allows user to store multiple point measurements. o Equipped
with RS232C terminal.
|
|
Benefits
|
- Easy user calibration with built-in calibration function.
- Capable to continuously monitor parameters via PC.
- Large LCD shows multiple parameters at a glance.
- Calculates
dew point, wet bulb
temperature, absolute humidity and humidity ratio.
|
|
Specifications
|
CO
|
Range |
0 to 500PPM
|
| Accuracy |
+/-3% of reading or +/-3PPM whichever is
greater
|
| Resolution |
0.1PPM: 0-99PPM 1PPM: 100-500 PPM
|
CO2
|
Range |
0
to 5000PPM |
| Accuracy |
+/-3% of reading or+/-50PPM whichever is
greater
|
| Resolution |
1PPM |
Temperature
|
Range
|
-
4 to 140F (-20 to 60C)
|
| Accuracy |
+/- 1F
(+/-0.5C) |
Resolution
|
0.1F (0.1C )
|
Relative Humidity
|
Range |
2 to 98%RH
|
| Accuracy |
2 to 80%RH:}2%RH, 80 to 98%RH:}3%RH
|
| Resolution |
0.1%RH
|
Function
|
Normal
Mode
|
Normal measuring (do not store and
calculate the data.) Relative humidity, CO, CO2, Dew point, Wet bulb
temperature, Absolute humidity and Humidity Ratio
|
Calculation
Mode
|
Store
the data, and calculate the maximum, minimum and average value.
|
%
OA Mode
|
Measure
ventilation ratio (Ask for ventilation ratio by calculating from
temperature and CO2 value)
|
Data
Output Mode
|
Perform
re-calculation of stored data and output of data to PC and Printer.
|
Calibration
Mode
|
Perform
the calibration of CO and CO2.
|
Output
|
Digital
|
RS232C
|
Analog (option)
|
DC
0 to 1V
|
| Power
Supply |
AAA
Battery x
4 (Mn, Alkaline, or Ni-Cd) |
Dimensions
|
Unit
|
3.5" x 7.5" x 2.0"
|
Probe
|
Length: 12.5 inch / Diameter: 1.0 inch
|
| Weight
(including batteries) |
Approx.
1.2 lbs
(500g) |
|
|
|
Accessories
|

|
 |
 |
|
Portable
Printer
|
AC Adapter
|
RS232
Cable
|
Carrying
Case
|
|
|
KANOMAX USA Copyright ©
2009 KANOMAX USA, INC. All Rights Reserved. |
 |
219 US Hwy. 206, PO Box 372, Andover, NJ 07821
Tel: (973)
786-6386 / Fax:
(973) 786-7586 / info@kanomax-usa.com |
|
|