• DIFFERENTIAL PRESSURE MANOMETER – DM4770AV
  • DIFFERENTIAL PRESSURE MANOMETER – DM4770AV
  • DIFFERENTIAL PRESSURE MANOMETER – DM4770AV
  • DIFFERENTIAL PRESSURE MANOMETER – DM4770AV
DIFFERENTIAL PRESSURE MANOMETER – DM4770AV
DIFFERENTIAL PRESSURE MANOMETER – DM4770AV
DIFFERENTIAL PRESSURE MANOMETER – DM4770AV
DIFFERENTIAL PRESSURE MANOMETER – DM4770AV

DIFFERENTIAL PRESSURE MANOMETER – DM4770AV

Request Quote DM4770AV

The DM4770AV Handheld Digital Manometer is now available with pressure, flow, and velocity measurements along with a number of other convenient features. The built-in air velocity and flow calculations provide accuracy and conserve time and error associated with manual calculations. Also featured on this unit are adjustable zero and span values for calibrating in the field, as well as a damping feature to compensate for the fluctuating of readings.

Calculates and displays air velocity and volumetric air flow

Rugged aluminum case protects instrument from damage during transport/use

9 selectable English and metric engineering units

Large, easy to read display with backlight for use in dark areas

Stores up to 40 readings with minimum, maximum and average statistics

Service Air and compatible gases.
Wetted Materials Consult factory.
Accuracy ±0.5% FS, 60 to 78°F (15.6 to 25.6°C); ±1.5% FS from 32 to 60°F and 78 to 104°F (0 to 15.6°C and 25.6 to 40.0°C).
Pressure Hysteresis ±0.1% of full scale.
Pressure Limits See chart on catalog page.
Temperature Limits 0 to 140°F (-17.8 to 60°C).
Compensated Temperature Limits 32 to 104°F (0 to 40°C).
Storage Temperature Limits -4 to 176°F (-20 to 80°C).
Display 0.42″ (10.6 mm) 4 digit LCD.
Resolution See chart on catalog page.
Units of Pressure in w.c., ft. w.c., in Hg, psi, oz/in², mm w.c., cm w.c., mm Hg, mbar, Pa, kPa, hPa.
Units of Velocity fpm, fps, mph, m/h, m/s, k/h, knot.
Units of Flow cfm, m3/h, m3/s.
Power Requirements 9 V Alkaline battery, installed non-functional, user replaceable.
Weight 10.2 oz (289 g).
Process Connections Two barbed connections for use with 1/8″ (3.18 mm) or 3/16″ (4.76 mm) ID tubing. Two compression fittings for use with 1/8″ (3.18 mm) ID x 1/4″ (6.35 mm) OD tubing for 477AV-7 and 477AV-8 only.
Agency Approvals CE..
We do not have an official recommended calibration interval. However, we would suggest checking the calibration at least once or twice a year depending on the application and how often the unit is used.
Unfortunately, we do not have any manometers available that can handle chlorine gas or sodium hydroxide (bleach).