• TRANSDUCER MODEL 6332/6332D
  • TRANSDUCER MODEL 6332/6332D
  • TRANSDUCER MODEL 6332/6332D
TRANSDUCER MODEL 6332/6332D
TRANSDUCER MODEL 6332/6332D
TRANSDUCER MODEL 6332/6332D

TRANSDUCER MODEL 6332/6332D

Request Quote

MODEL 6332/6332D TRANSDUCER MODULE

6332/6332D FEATURES

  • Analog output makes it easy to integrate with other equipment
  • Smart probe technology lets you change probes without recalibrating the transducer
  • Purchase probes separately and choose the ones that meet your application needs
  • Quality Control monitoring and controlling air velocity and distribution during drying/ shaping process
  • Combined with thermographic system measure air velocity across the board to evaluate the cooling efficiency
  • 6332D comes with a display 6332 does not have a display
  • Airflow transducers are designed for fixed installation
  • Use on your production line quality control system
  • Monitor facility exhaust ventilation system.
  • Transducers feature 0 to 5 VDC or 4 to 20 mA analog output so you can send your data to other instruments such as data loggers, alarms, or controllers.
  • Selectable Output (Output can be set to either voltage (0 to 5V) or current (4 to 20mA))

Quality inspection of factory inspection line

Evaluation of thermal measures for PCBs

Air volume monitoring of local ventilation system

24-hour monitoring of in-house ventilation

Monitoring airflow in indoor farms

blog featured img

General Specifications
Analog Output Current output: DC 4~20mA (Max. load resistance: 250Ω)
Voltage output: DC 0~5V
Display Resolution (Model 6332D only) 0.01m/s (Velocity Range: 0 to 2, 0 to 5, 0 to 10 m/s)
0.1m/s (Velocity Range: 0 to 25, 0 to 50 m/s)
Response Time Display: 0.3 second Sampling: 0.1 second Output: 0.1 second
Power Supply DC 12 to 24V
Operating Temperature Range 41 to 104 ºF (5 to 40 ºC) with no condensation
Storage Temperature Range 14 to 122°F (-10 to 50°C) with no condensation
Dimensions 128(W)×78(D)×30(H) mm
Weight 0.7 lbs (320g)
Warranty 1 year
What’s Included Meter, Operation Manual
Airflow Transducer Probes (See Table Below)
Measurement Specifications
Air Velocity
Ranges 0.1 to 25.0 m/s
0.1 to 50.0 m/s
Accuracy +/- (3% of READING +/- 0.1) m/s
Operating Temperature Range -4 to 158°F (-20 to 70°C) with no condensation
Storage Temperature Range 14 to 122°F (-10 to 50°C) with no condensation
Warranty 1 year
What’s Included Probe, Data ROM, NIST TRACEABLE CALIBRATION Certificate

Transducer Probes

0962-00 0963-00 0965-00 0965-01 0965-03 0965-04 0965-07 0965-08 0965-09 0965-10
Air Velocity Range (m/s) 0.1 to 50.0 0.1 to 50.0 0.1 to 25.0 0.1 to 25.0 0.1 to 25.0 0.1 to 25.0 0.1 to 25.0 0.1 to 25.0 0.1 to 50.0 0.1 to 50.0
Airflow Directivity Mono Mono Mono Omni Omni Omni Omni Omni Omni Omni
Probe Type Rod Rod Spherical Spherical Miniature Miniature Miniature Miniature Spherical Spherical
Air Velocity O O O O O O O O O O

They measure the air speed by calculating how fast the probe sensor is being cooled by the airflow.

The principles behind all hot-wire anemometers may be the same, but the quality varies. Simply put, with our temperature compensation sensor, our Climomaster is the most accurate with an accuracy of +/- 2%. This is due to several factors:

1) We calibrate the temperature compensation sensor, as well as the velocity sensor. Other manufacturers only calibrate the velocity sensor.

2)We use special high-quality materials, like our platinum sensors, that increase accuracy.

3) Our manufacturing facility uses not 1, but 4 specialized wind tunnels to test and calibrate our anemometers. These wind tunnels include a low velocity tunnel, high tunnel velocity and a variable temperature wind tunnel.

4) We’ve been making anemometers for over 80 years. During that time we’ve perfected our knowledge and refined our manufacturing process to produce a research-grade instrument.

Yes, all our instruments come with a calibration certificate.

Kanomax recommends annual calibration to ensure accuracy.

No, these are thermal anemometers that generate heat when in operation; if you expose them to a flammable gas it could cause a fire or explosion. Corrosive or caustic gases, such a chlorine, will damage the sensor on contact. While it is possible to use the instrument in a non-flammable, non-caustic gases the instrument is not calibrated for these gases and it will not measure airflow accurately.

Give us a call! Our customer service team is happy to discuss your application and find a solution that works for you. We won’t sell you a product that doesn’t meet your needs.

Related Products